商品搜尋
商品搜尋
行業別
功能
Banner

產品&服務

HITI Industrial Automation

E2NC

E2NC

產品特色
Smart Proximity Sensor with Separate Amplifier Enables Easily Making Highprecision Sensitivity Settings.

• Wide variety of Sensor Heads to select according to the application. Flexible cables are used between Preamplifiers and Amplifier Units of the Sensor Heads.

• High resistance to changes in ambient temperature. Temperature characteristics of 0.08%/°C *

• Make simple and reliable detection settings with micronlevel precision using the teaching function.

• Check the sensing excess gain level on the digital display.

• Support for high-precision positioning and screening with fine positioning to maximize variations.

• The Model for Sensor Communications Units support an EtherCAT Sensor Communications Unit or CC-Link Sensor Communications Unit.

* Refer to the Specifications.

Sensors

Sensor Heads

Type Appearance Sensing
Distances
Repeat
accuracy
Cable specification Model
Shielded Cylindrical
3700_lu_1_1
3 dia. × 18 mm 0.6 mm 1 μm Free cutting *2 E2NC-EDR6-F
5.4 dia. × 18 mm 1 mm 1 μm Standard *2 E2NC-ED01
Free cutting *2 E2NC-ED01-F
With Protective
Spiral Tube *1*2
E2NC-ED01-S
8 dia. × 22 mm 2 mm 2 μm Standard *2 E2NC-ED02
Free cutting *2 E2NC-ED02-F
With Protective
Spiral Tube *1*2
E2NC-ED02-S
Screw
3700_lu_1_2
M10 × 22 mm 2 mm 2 μm Standard *2 E2NC-EM02
Free cutting *2 E2NC-EM02-F
With Protective
Spiral Tube *1*2
E2NC-EM02-S
Flat
3700_lu_1_3
30 × 14 × 4.8 mm 5 mm 2 μm Standard *2 E2NC-EV05
Free cutting *2 E2NC-EV05-F
With Protective
Spiral Tube *1*2
E2NC-EV05-S
Unshielded Screw
3700_lu_1_4
M18 × 46.3 mm 7 mm 5 μm Standard *2 E2NC-EM07M
Free cutting *2 E2NC-EM07M-F
With Protective
Spiral Tube *1*2
E2NC-EM07M-S
Heat-
resistant
Screw
3700_lu_1_5
M12 × 22 mm 2 mm 2 μm Standard *2 E2NC-EM02H

*1. Ask your OMRON representative for information on the Protective Spiral Tube.
*2. Standard models and models with Protective Spiral Tube: The standard cable length is 2.6 m, Free-cut models: The
standard cable length is 3.6 m. (Standard cable length is the length containing the preamplifier and connector.)

Amplifier Units

Type Appearance Connection method Input/output Model
NPN output PNP output
Advanced models 3700_lu_2_1 Pre-wired (2 m) 2 outputs + 1 input E2NC-EA21 2M E2NC-EA51 2M
3700_lu_2_2 Wire-saving Connectors 2 outputs E2NC-EA7TW E2NC-EA9TW
3700_lu_2_3 Wire-saving Connectors 1 output + 1 input E2NC-EA7 E2NC-EA9
Model for Sensor
Communications
Unit *
3700_lu_2_4 Connector for Sensor
Communications Unit
--- E2NC-EA0
3700_lu_2_5 Connector for Sensor
Communications Unit
Pre-wired (2 m)
1 output E2NC-EA10 2M E2NC-EA40 2M

* A Sensor Communications Unit is required if you want to use the Amplifier Unit on a network.

Accessories (Sold Separately)

Wire-saving Connectors (Required for models for Wire-saving Connectors.)

Connectors are not provided with the Fiber Amplifier Unit and must be ordered separately.
*Protective stickers are provided.

Type Appearance Cable length No. of conductors Model Applicable Amplifier Units
Master Connector 3700_lu_3_1 2 m 4 E3X-CN21 E2NC-EA7TW
E2NC-EA9TW
E2NC-EA7
E2NC-EA9
Slave Connector 3700_lu_3_2 2 E3X-CN22

End Plate

Two End Plates (PFP-M) are provided with the Sensor Communications Unit.
End Plates (PFP-M and E39-EP1) are not provided with the Amplifier Unit. They must be ordered separately as required.

Appearance Model Quantity Applicable Amplifier Units
3700_lu_4_1 PFP-M 1 E2NC-EA21
E2NC-EA51
E2NC-EA7[][]
E2NC-EA9[][]
E2NC-EA0
3700_lu_4_2 E39-EP1 1 E2NC-EA10
E2NC-EA40

Related Products

Sensor Communications Units

Type Appearance Model
Sensor Communications Unit for EtherCAT 3700_lu_5_1 E3NW-ECT
Sensor Communications Unit for CC-Link 3700_lu_5_2 E3NW-CCL
Distributed Sensor Unit * 3700_lu_5_3 E3NW-DS

Refer to your OMRON website for details.
* The Distributed Sensor Unit can be connected to any of the Sensor Communications Units.

EtherCAT® is a registered trademark and patented technology, licensed by Beckhoff Automation GmbH, Germany.
CC-Link is a registered trademark of Mitsubishi Electric Corporation. The trademark is managed by the CC-Link Partner Association.

Sensor Heads

Model E2NC-EDR6-F E2NC-ED01(-[]) E2NC-ED02(-[]) E2NC-EM02(-[])
3 dia. × 18 mm 5.4 dia. × 18 mm 8 dia. × 22 mm M10 × 22 mm
Sensing Distances 0.6 mm 1 mm 2 mm 2 mm
Sensing object Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to
Engineering Data on Data Sheet.)
Standard sensing object 5 × 5 mm 5 × 5 mm 10 × 10 mm 10 × 10 mm
Material: iron (t = 3, S50C)
Repeatability *1 1 μm 1 μm 2 μm 2 μm
Hysteresis distance Variable
Temperature
characteristics
*2
Sensor Head 0.3%/°C 0.08%/°C 0.08%/°C 0.08%/°C
Preamplifier
and Amplifier
0.08%/°C
Ambient
temperature
range *3
Operating -10°C to 60°C (with no icing or condensation)
Storage -10°C to 60°C
(with no icing or
condensation)
-20°C to 70°C (with no icing or condensation)
Ambient humidity Operating/storage: 35% to 85% (with no condensation)
Insulation resistance 50 MΩ min. (at 500 VDC)
Dielectric strength 1,000 VAC at 50/60 Hz for 1 min between current carry parts and case
Vibration resistance
(destruction)
10 to 55 Hz with a 1.5-mm double amplitude for 2 hours each in X, Y, and Z
directions
Shock resistance (destruction) 500 m/s2 for 3 times each in X, Y, and Z directions
Degree of protection (Sensor
Head)
IEC60529 IP67
Weight (packed state) *6 Approx. 120 g
Materials Sensor Head Brass SUS Brass Brass
Sensing surface Heat-resistant ABS
Clamping nut --- Nickel-plated
brass
Toothed washer --- Zinc-plated iron
Preamplifier PES
Connection method *7 Connector (Standard models and models with Protective Spiral Tube: The standard
cable length is 2.6 m, Free-cut models: The standard cable length is 3.6 m.)
Accessories Instruction Manual, Mounting Brackets

Model E2NC-EV05(-[]) E2NC-EM07M(-[]) E2NC-EM02H
30 × 14 × 4.8 mm M18 × 46.3 mm M12 × 22 mm
Sensing Distances 5 mm 7 mm 2 mm
Sensing object Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to
Engineering Data on Data Sheet.)
Standard sensing object 15 × 15 mm 22 × 22 mm 20 × 20 mm
Material: iron (t = 3, S50C)
Repeatability *1 2 μm 5 μm 2 μm
Hysteresis distance Variable
Temperature
characteristics
*2
Sensor Head 0.04%/°C 0.08%/°C 0.2%/°C
Preamplifier
and Amplifier
0.08%/°C
Ambient
temperature
range *3
Operating -10°C to 60°C (with no icing or condensation) -10°C to 200°C
(with no icing or
condensation) *4
Storage -20°C to 70°C (with no icing or condensation)
Ambient humidity Operating/storage: 35% to 85% (with no condensation)
Insulation resistance 50 MΩ min. (at 500 VDC)
Dielectric strength 1,000 VAC at 50/60 Hz for 1 min between current carry parts and case
Vibration resistance
(destruction)
10 to 55 Hz with a 1.5-mm double amplitude for 2 hours each in X, Y, and Z
directions
Shock resistance (destruction) 500 m/s2 for 3 times each in X, Y, and Z directions
Degree of protection (Sensor
Head)
IEC60529 IP67 IEC60529 IP60 *5
Weight (packed state) *6 Approx. 120 g
Materials Sensor Head Zinc Brass Brass
Sensing surface Heat-resistant ABS PEEK
Clamping nut --- Nickel-plated brass
Toothed washer --- Zinc-plated iron
Preamplifier PES PEEK
Connection method *7 Connector (Standard models and models with Protective Spiral Tube: The standard
cable length is 2.6 m, Free-cut models: The standard cable length is 3.6 m.)
Accessories Instruction Manual, Mounting Brackets

*1. Repeatability: The standard reference object at 1/2 of the measurement range.
*2. Temperature characteristic: The standard reference object at 1/2 of the measurement range.
*3. Do not expose the product to rapid temperature changes, otherwise the characteristics may be deteriorated.
*4. Sensor Head only (The ambient temperature of other parts is -10 to 60°C)
*5. Do not expose the product to steam. This product does not have any protection mean against water.
*6. The protective spiral tube adds another 90 g to the weight.
*7. Standard length is the length containing the preamplifier and connector.

Amplifier Unit

Types Advanced models Model for Sensor
Communications Unit *1
NPN output E2NC-EA21 E2NC-EA7TW E2NC-EA7 E2NC-EA10 E2NC-EA0
PNP output E2NC-EA51 E2NC-EA9TW E2NC-EA9 E2NC-EA40
Connecting method Pre-wired
(2 m)
Wire-saving Connectors Connector for
Sensor Com-
munications
Unit Pre-
wired (2 m)
Connector for
Sensor Com-
munications
Unit
Input/
output
Output 2 outputs 1 output 1 output *2 2 outputs *3
External
inputs *4
1 input --- 1 input --- ---
Power supply voltage 10 to 30 VDC, including 10% ripple (p-p) Refer to the communication unit
specifications.
Power consumption *5 At Power Supply Voltage of 24 VDC
Normal mode: 1,080 mW max. (Current consumption at 45 mA max.),
Eco function ON: 840 mW max. (Current consumption at 35 mA max.),
Eco function LO: 960 mW max. (Current consumption at 40 mA max.)
Control output Load power supply voltage: 30 VDC max., open collector output
Load current: Groups of 1 to 3 Amplifier Units: 100 mA max., Groups of
4 to 30 Amplifier Units: 20 mA max.
Residual voltage:
At load current of less than 10 mA: 1 V max.
At load current of 10 to 100 mA: 2 V max.
OFF current: 0.1 mA max.
Refer to the
communication
unit
specifications.
Indicators 7-segment displays (Sub digital display: green, Main digital display: white)
Display direction: Switchable between normal and reversed.
OUT indicator (orange), NO/NC indicator (orange), ST indicator (blue) and
OUT selection indicator (orange, only on models with 2 outputs)
Protection circuits Power supply reverse polarity protection, output short-circuit protection and output reverse polarity protection Power supply
reverse polarity
protection,
output
short-circuit
protection
Response
time
Super-high-
speed mode
(SHS)
Operate or reset: 150 μs
High-speed
mode (HS)
Operate or reset: 300 μs (default setting)
Standard
mode (Stnd)
Operate or reset: 1 ms
GIGA power
mode (GIGA)
Operate or reset: 4 ms
Sensitivity adjustment Smart Tuning (Fine Positioning, 2-point Tuning, Position Tuning, Percentage Tuning (-99% to
99%), Full Auto Tuning, or manual adjustment
Maximum connectable
Units
16 units With E3NW-ECT:
30 units *6
With E3NW-CCL:
16 units
No. of Units for mutual
interference prevention
Up to five units, intermittent oscillation method
(response time = (No. of connected units + 1) x 15 ms)
Note: The mutual interference prevention function is disabled if Super High Speed
mode (SHS) is selected for detection function.
Functions Operation
mode
NO (Normally Open)/NC (Normally closed)
Timer Select from timer disabled, OFF-delay, ON-delay, one-shot, or ON-delay + OFF-delay timer:
1 to 9,999 ms
Differential
detection
Single edge: Can be set to 250 μs, 500 μs, 1 ms, 10 ms, or 100 ms.
Zero reset Provided
Zero-reset is accompanied by a change of detection distance.
After zero-reset, some threshold level may also cause a change of the indication by influence
of other settings.
Resetting
settings *7
Select from initial reset (factory defaults) or user reset (saved settings).
Eco mode Select from OFF (digital display lit), Eco ON (digital display not lit), and Eco LO (digital display
dimmed).
Bank
switching
Select from banks 1 to 4.
Output 1 Select from normal detection mode, area detection mode or differential detection mode.
Output 2 Select from normal detection
mode, alarm output mode, error
output mode or disconnection
detection output mode.
--- --- Select from
normal detection
mode, alarm
output mode,
error output mode
or disconnection
detection output
mode.
External
input
Select from input
OFF, 2-point
Tuning, Percent-
age Tuning, Full
Auto Tuning, Fine
Positioning, zero
reset,
synchronization
detection, or bank
switching.
--- Select from input
OFF, 2-point
Tuning, Percent-
age Tuning, Full
Auto Tuning, Fine
Positioning, zero
reset,
synchronization
detection, or bank
switching.
--- ---
Hysteresis
width
Select from standard setting or user setting. For a user setting, the hysteresis width can be
set from 0 to 9,999.
Changing
the displays
Threshold/Detected intensity ratio, Peak receiving
Detected amount/Bottom Detected amount,
Threshold bar display, Peak Detected amount/
Receiving Detected and CH number/Detected amount
Threshold/ Detected intensity ratio,
Peak receiving Detected amount/
Bottom Detected amount, Threshold
bar display, Peak Detected amount/
Receiving Detected and CH number/
Detected amount
Ambient temperature
range
Operating:
Groups of 1 or 2 Amplifier Units: -25 to 55°C,
Groups of 3 to 10 Amplifier Units: -25 to 50°C,
Groups of 11 to 16 Amplifier Units: -25 to 45°C,
Groups of 17 to 30 Amplifier Units: -25 to 40°C
Storage: -30 to 70°C (with no icing or condensation)
Operating:
Groups of 1 or 2 Amplifier Units:
0 to 55°C,
Groups of 3 to 10 Amplifier Units:
0 to 50°C,
Groups of 11 to 16 Amplifier Units:
0 to 45°C,
Groups of 17 to 30 Amplifier Units:
0 to 40°C
Storage: -30 to 70°C (with no icing
or condensation)
Ambient humidity range Operating and storage: 35 to 85% (with no condensation) within the surrounding air
temperature range shown above
Altitude 2,000 m max.
Installation environment Pollution degree 3
Insulation resistance 20 MΩ min. (at 500 VDC)
Dielectric strength 1,000 VAC at 50/60 Hz for 1 min
Vibration resistance
(destruction)
10 to 55 Hz with a 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance
(destruction)
500 m/s2 for 3 times each in X, Y, and Z directions 150 m/s2 for 3 times each in X, Y,
and Z directions
Weight (packed state/
Sensor only)
Approx. 115 g/
Approx. 75 g
Approx. 60 g/
Approx. 20 g
Approx. 60 g/
Approx. 20 g
Approx. 95 g/
Approx. 45 g
Approx. 65 g/
Approx. 25 g
Materials Case Polycarbonate (PC)
Cover Polycarbonate (PC)
Cable PVC
Accessories Instruction Manual

*1. The communication unit is compatible with EtherCAT type E3NW-ECT and E3NW-CCL of CC-Link. This unit is not usable
with E3NW-CRT.
*2. Channel 1 of each amplifier unit is output as the output drawn by the cord.
*3. Output signals from two sensors are assigned to the PLC via the network.
Various settings can be changed and detected values can be read by operating the PLC via the network.
*4. The following details apply to the input.

Contact input (relay or switch) Non-contact input (transistor) Input time
*4-1
NPN output
E2NC-EA21
E2NC-EA7
ON: Shorted to 0 V (Sourcing current:
1 mA max.).
OFF: Open or shorted to Vcc.
ON: 1.5 V max. (Sourcing current: 1 mA max.)
OFF: Vcc - 1.5 V to Vcc (Leakage current:
0.1 mA max.)
ON: 9 ms min.
OFF: 20 ms min.
PNP output
E2NC-EA51
E2NC-EA9
ON: Shorted to Vcc (Sinking current:
3 mA max.).
OFF: Open or shorted to 0 V.
ON: Vcc - 1.5 V to Vcc (Sinking current: 3 mA
max.)
OFF: 1.5 V max. (Leakage current: 0.1 mA max.)

*4-1. Input time is 25 ms (ON)/(OFF) only when (in tUnE) or (in PtUn) input is selected.
*5. At Power supply voltage of 10 to 30 VDC
Normal mode: 1,110 mW max. (Current consumption: 37 mA max. at 30 VDC, 76 mA max. at 10 VDC)
Eco function ON: 900 mW max. (Current consumption: 30 mA max. at 30 VDC, 48 mA max. at 10 VDC)
Eco function LO: 1,020 mW max. (Current consumption: 34 mA max. at 30 VDC, 58 mA max. at 10 VDC)
*6. When connected to an OMRON NJ-series Controller. For details, refer to the communication unit manual.
*7. The bank is not reset by the user reset function or saved by the user save function.

(單位:mm)

Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified.

Sensor Heads

E2NC-EDR6-F

E2NC 外觀尺寸 3

E2NC-ED01(-F)

E2NC 外觀尺寸 4

E2NC-ED01-S

E2NC 外觀尺寸 5

E2NC-ED02(-F)

E2NC 外觀尺寸 6

E2NC-ED02-S

E2NC 外觀尺寸 7

E2NC-EM02(-F)

E2NC 外觀尺寸 8

E2NC-EM02-S

E2NC 外觀尺寸 9

E2NC-EM07M(-F)

E2NC 外觀尺寸 10

E2NC-EM07M-S

E2NC 外觀尺寸 11

E2NC-EV05(-F)

E2NC 外觀尺寸 12

E2NC-EV05-S

E2NC 外觀尺寸 13

E2NC-EM02H

E2NC 外觀尺寸 14

Amplifier Unit

Pre-wired Amplifier Units

E2NC-EA21
E2NC-EA51

E2NC 外觀尺寸 16

Amplifier Units with Wire-saving Connectors

E2NC-EA7TW
E2NC-EA9TW
E2NC-EA7
E2NC-EA9

E2NC 外觀尺寸 17

Amplifier Unit with Connector for Sensor Communications Unit

E2NC-EA0

E2NC 外觀尺寸 18

Amplifier Unit with Connector for Sensor Communications Unit (Pre-wired)

E2NC-EA10
E2NC-EA40

E2NC 外觀尺寸 19

Accessories (Sold Separately)

Wire-saving Connectors

Master Connector
E3X-CN21

E2NC 外觀尺寸 21

Slave Connector
E3X-CN22

E2NC 外觀尺寸 22

Mounting Bracket

E39-L143

E2NC 外觀尺寸 23

Material: Stainless steel (SUS304)

End Plate

PFP-M

E2NC 外觀尺寸 25

Materials: Iron, zinc plating

E39-EP1

E2NC 外觀尺寸 27

Materials: SUS304 CP

English

Global Edition

以下是海外共通的產品型錄,其中可能包含不在台灣銷售的型號。

在台灣訂購時請注意確認。

※若型錄PDF檔案太大,建議按滑鼠右鍵"另存目標"下載。

Catalog Name Catalog Number
[size]
Last Update
E2NC Series Data Sheet E473-E1-02
[7764KB]
Mar 01, 2021
20210301
E2NC Series Data Sheet
如有需要請洽各所營業人員

誠睿台南所 TEL:06-2493086
誠睿台中所 TEL:04-23380790
誠睿新竹所 TEL:03-6685558
客服信箱 service@hitifa.com.tw
如有需要請洽各所營業人員

誠睿台南所 TEL:06-2493086
誠睿台中所 TEL:04-23380790
誠睿新竹所 TEL:03-6685558
客服信箱 service@hitifa.com.tw
更多案例 更多產品 TOP