New and improved design for easier use, programming, maintenance and user feedback. The improved user interface is intuitive and offers better overall visibility. Replacement time notification function notifies the user of potential preventive maintenance

New and improved design for easier use, setting and maintenace

The H7CC series improves overall user experience through better visual feedback and operation, user interface and predictive remaining lifetime of counter.

The improved user interface is intuitive and offers better overall visibility

H7CC-R 特長 2

Intuitive LED user-interface guide

H7CC-R 特長 3

Optimized wiring design

Power supply and input have been isolated, eliminating special considerations for grounding or leakage current.

H7CC-R 特長 4

Replacement time notification function notifies the user of potential preventive maintenance

[From] Have you ever looked at a counter to find that it has stopping functioning properly?

When a counter’s service life expires, there are multiple ways it can potentially fail. For example, it may stop suddenly or become incapable of performing certain control functions.
Preventative maintenance to avoid such mechanical failures or identifying the cause when such a failure occurs, may require a significant effort and time.

H7CC-R 特長 7

A single error may have several contributing factors

[To] Prevents unexpected downtime by communicating device replacement timing

When an H7CC Series counter reaches its replacement time, it will visually notify the user via its display by flashing the count value and “RPLC” alternately in one second intervals.

H7CC-R 特長 8

Tool for easily calculating counter replacement time

The rate at which an electrolytic capacitor deteriorates varies according to its use environment. Omron offers a tool that allows you to easily calculate your H7CC counter’s replacement time, according to the conditions your using it in.

Control devices, including counters, have a limited service life

Each counter has its limited service life.
The standard service life of a relay output contact is 100,000 operations. Factoring in the deterioration of the built-in electrolytic capacitors, Omron recommends that a counter be replaced approximately every 7 to 10 years depending on environment. A counter that is used beyond its service life may fail, potentially emitting smoke or odor.

H7CC-R 特長 10

*1. Compared with the previous products
*2. The AC power supply ground is on the commercial power supply side.

Model Number Legend (Not all possible combinations of functions are available.)

H7CC-R 種類 1

List of Models

Classification Configuration External
connections
Settings Display
digits
Outputs Power
supply
voltage
Model
Tachometer • Tachometer 11-pin socket 1-stage
(1 input
and
output)
6 digits Contact output
(SPDT)
100 to
240 VAC
H7CC-R11
24 VAC/
12 to 48
VDC
H7CC-R11D
1 stage
(2 inputs
and
outputs)
Contact output
(SPDT+SPST)
100 to
240 VAC
H7CC-R11W
24 VAC/
12 to 48
VDC
H7CC-R11WD

Accessories (Order Separately)

Soft Cover

Model Remarks
Y92A-48F1 ---

Hard Cover

Model Remarks
Y92A-48 ---

Flush Mounting Adapter

Model Remarks
Y92F-30 Included with models with screw terminals.
Y92F-45 Use this Adapter to install the Counter/Tachometer in a cutout previously made
for a DIN 72 × 72 mm device (panel cutout: 68 × 68 mm).

Waterproof Packing

Model Remarks
Y92S-P6 Included with models with screw terminals.

Connection Sockets

Model Classification Connectable
Counter/
Tachometers
Remarks
P2CF-08 Front-connecting Socket H7CC-[]8 ---
P2CF-08-E Front-connecting Socket
(Finger-safe Type)
Round crimp terminals cannot be used on
Finger-safe Sockets.
Use forked crimp terminals.
P3G-08 Back-connecting Sockets A Y92A-48G Terminal Cover can be used with
the Socket to create a finger-safe construction.
P2CF-11 Front-connecting Socket H7CC-[]11 ---
P2CF-11-E Front-connecting Socket
(Finger-safe Type)
Round crimp terminals cannot be used on
Finger-safe Sockets.
Use forked crimp terminals.
P3GA-11 Back-connecting Sockets A Y92A-48G Terminal Cover can be used with
the Socket to create a finger-safe construction.

Terminal Covers for P3GA-11 Back-connecting Socket

Model Remarks
Y92A-48G ---

Ratings

Classification Tachometer
Item H7CC-R11[] H7CC-R11W[]
Input mode 1 input only 2 inputs only
Ratings Power supply
voltage *1
• 100 to 240 VAC, 50/60 Hz
• 12 to 24 VDC or 48 VAC, 50/60 Hz
Operating
voltage
fluctuation
range
85% to 110% of rated supply voltage (90% to 110% at 12 to 48 VDC)
Power
consumption
Approx. 6.8 VA at 100 to 240 VAC,
Approx. 5.5 VA/ 3.3 W at 24 VAC/12 to 48 VDC
Mounting method Flush mounting or surface mounting
External connections 11-pin socket
Degree of protection IEC IP66 for panel surface only and when Y92S-P6 Waterproof Packing is used
Input signals Count and hold Count 1 and count 2
Pulse measurement method Tachometer mode (cycle measurement) AMD-compatible mode (continuous
measurement)
Tachometer mode (cycle measurement)
Maximum counting speed 30 Hz
(minimum pulse
width: 16.7 ms)
10 kHz
(minimum pulse
width: 0.05 ms)
--- 30 Hz (minimum pulse width: 16.7 ms) or
5 kHz (minimum pulse width: 0.1 ms)
(selectable)
Minimum input signal width --- 10 ms 1 ms ---
Measuring ranges 0.001 Hz to 30.00Hz 0.001 Hz to 10 kHz 0.026 to 999999 s 0.003 to 999999 s 0.01 to 5k Hz
Sampling cycle 200 ms min. Continuous measurement
(minimum interval of 10 ms)
200 ms min.
Display refresh cycle • Input pulse of 5 Hz min.
Averaging not used: 200 ms
Averaging used: 200 multiplied by the averaging setting (ms)
• Input pulse of less than 5 Hz
Averaging not used: Two times the maximum input pulse cycle
Using averaging: Two times the maximum of the input pulse cycle multiplied by the averaging setting.
Measuring accuracy ±0.1% FS ±1 digit max. (at 23 ±5°C)
Output mode HI-LO, AREA, HI-HI, LO-LO HI-HI, LO-LO
Auto-zero time 0.1 to 999.9 s (in Tachometer Mode)
Startup time 0.0 to 99.9 s
Averaging Simple averaging/moving averaging selectable, Number of times: OFF, 2, 4, 8 or 16 times
Prescaling function 0.001 to 99.999 (in Tachometer Mode)
Decimal point adjustment Rightmost 3 digits ---
Sensor waiting time 290 ms max. (Control output is turned OFF and no input is accepted during sensor waiting time.)
Input Input method No-voltage Input
Impedance when ON: 1 kΩ max. (Leakage current: 12 mA when 0 Ω)
ON residual voltage: 3 V max.
Impedance when OFF: 100 kΩ min.
Voltage Input
High (logic) level: 4.5 to 30 VDC
Low (logic) level: 0 to 2 VDC (Input resistance: approx. 4.7 kΩ)
Hold input Minimum input signal width: 20 ms ---
External power supply 12 VDC (±10%), 100 mA
* Refer to Safety Precautions (Common) for details.
Control output Contact output: 3 A at 250 VAC/30 VDC, resistive load (cosφ=1)
Minimum applied load:10 mA at 5 VDC (failure level: P, reference value)
Display *2 7-segment, negative transmissive LCD
Character height
Present value: 10 mm (white), comparison value: 6 mm (green)
Digits 6 digits (0 to 999999)
Memory backup Non-volatile memory (overwrites: 100,000 times min.) that can store data for 10 years min.
Operating temperature range -10 to 55°C (-10 to 50°C if Counter/Tachometers are mounted side by side) (with no icing or condensation)
Storage temperature range -25 to 70°C (with no icing or condensation)
Operating humidity range 25% to 85%
Case color Black (N1.5)

*1. Do not use the output from an inverter as the power supply. The ripple must be 20% maximum for CC power.
*2. The display is lit only when the power is ON. Nothing is displayed when power is OFF.

Characteristics

Insulation resistance 100 MΩ min. (at 500 VDC) between current-carrying terminal and exposed non-current-
carrying metal parts, and between non-continuous contacts
Dielectric strength 2,000 VAC, 50/60 Hz for 1 min between current-carrying metal parts and non-current-carrying metal parts
2,000 VAC (for 100 to 240 VAC), 50/60 Hz for 1 min between power supply and input
circuit (1,500 VAC for 24 VAC/12 to 48 VDC)
2,000 VAC 50/60 Hz for 1 min between control output, power supply, and input circuit
1,000 VAC, 50/60 Hz for 1 min between non-continuous contacts
Impulse withstand voltage 6.0 kV (between power terminals) for 100 to 240 VAC, 1.0 kV for 24 VAC/12 to 48 VDC
6.0 kV (between current-carrying terminal and exposed non-current-carrying metal
parts) for 100 to 240 VAC, 1.5 kV for 24 VAC/12 to 48 VDC
Static immunity Destruction: 15 kV, Malfunction: 8 kV
Vibration
resistance
Destruction 10 to 55 Hz with 0.75-mm single amplitude, each in three directions for 2 hours
Malfunction 10 to 55 Hz with 0.35-mm single amplitude, each in three directions for 10 min
Shock
resistance
Destruction 300m/s2 each in three directions, three cycles
Malfunction 100m/s2 each in three directions, three cycles
Life expectancy Mechanical: 10,000,000 operations min.
Electrical: 100,000 operations min. (3 A at 250 VAC, resistive load, ambient
temperature condition: 23°C) *
Weight Approx. 100 g (Tachometer only)

* See Life-test Curve (Reference Values) .

Life-test Curve (Reference Values)

H7CC-R 額定/性能 5
H7CC-R 額定/性能 6

A current of 0.15 A max. can be switched at125 VDC (cosφ=1) (Life expectancy: 100,000operations)
A current of 0.1 A max. can be switched ifL/R=7 ms.
(Life expectancy: 100,000 operations)

Applicable Standards

Approved
safety
standards
cULus (or cURus): UL508/CSA C22.2 No. 14 *1
Conforms to EN 61010-1 (IEC 61010-1): Pollution degree 2/overvoltage category II, EAC, RCM,
B300 PILOT DUTY, 1/4 HP 120 VAC, 1/3 HP, 240 VAC, 3-A, 250 VAC/30 VDC resistive load
VDE0106/part100
EMC (EMI) EN61326-1 *2
Emission Enclosure: EN55011 Group 1 classA
Emission AC mains: EN55011 Group 1 classA
(EMS) EN61326-1 *2
Immunity ESD: EN61000-4-2:
4 kV contact discharge (level 2); 8 kV air discharge (level 3)
Immunity RF-interference: EN61000-4-3:
10 V/m (Amplitude-modulated, 80 MHz to 1 GHz)
3 V/m (Amplitude-modulated, 1.4 G to 2 GHz)
1 V/m (Amplitude-modulated, 2 G to 2.7 GHz)
10 V/m (Pulse-modulated, 900 MHz ±5 MHz)
Immunity Conducted Disturbance: EN61000-4-6: 10 V (0.15 to 80 MHz) (level 3)
Immunity Burst: EN61000-4-4:
2 kV power-line (level 3); 1 kV I/O signal-line (level 4)
Immunity Surge: EN61000-4-5:
1 kV line to lines (power and output lines) (level 2);
2 kV line to ground (power and output lines) (level 3)
Immunity Voltage Dip/Interruption: EN61000-4-11:
Voltage Dip
1 cycle, 100%(rated voltage)
10/12 cycle, 60%(rated voltage)
25/30 cycle, 30%(rated voltage)
Interruption
250/300 cycle, 100%(rated voltage)

*1. The following safety standards apply to the H7CC-R11[].
cUL (Listing): Applicable when an OMRON P2CF(-E) Socket is used.
cUR (Recognition): Applicable when any other socket is used.
*2. Industrial electromagnetic environment (EN/IEC 61326-1 Table 2)

I/O Functions

Inputs Count, count 1,
count 2
Reads counting signals.
Hold • Holds the measurement value and outputs.
• The hold indicator is lit during hold. *
Outputs OUT, OUT1, OUT2 Outputs signals according to the specified output
mode when a comparison value is reached.

* Refer to Catalog for details on the hold function.

(單位:mm)

Tachometers

Dimensions without Flush Mounting Adapter
H7CC-R[]

H7CC-R 外觀尺寸 2

Dimensions with Flush Mounting Adapter
(Adapter and Waterproof Packing Ordered Separately)
H7CC-R[]

H7CC-R 外觀尺寸 3

Panel Cutouts

Panel cutouts are as shown below (according to DIN43700).

H7CC-R 外觀尺寸 4

Note:
1. The mounting panel thickness should be 1 to 5 mm.
2. To allow easier operation, it is recommended that Adapters be mounted so that the gap between sides with hooks is at least 15 mm (i.e., with the panel cutouts separated by at least 60 mm).
3. It is possible to horizontally mount Timers side by side. Attach the Flush Mounting Adapters so that the surfaces without hooks are on the sides of the Timers. If Counters/Tachometers are mounted side by side, however, water resistance will be lost.

H7CC-R 外觀尺寸 5

Dimensions with Front Connecting Socket
H7CC-R[]

H7CC-R 外觀尺寸 6

Accessories (Order Separately)

Note: Depending on the operating environment, the condition of resin products may deteriorate, and may shrink or become harder. Therefore, it is recommended that resin products are replaced regularly.

Soft Cover
Y92A-48F1

H7CC-R 外觀尺寸 8

Hard Cover
Y92A-48

H7CC-R 外觀尺寸 9

Protecting the Counter/Tachometer in Environments Subject to Oil

The H7CC's panel surface is water-resistive (conforming to IP[]6) and so even if drops of water penetrate the gaps between the keys, there will be no adverse effect on internal circuits. If, however, there is a possibility of oil being present on the operator's hands, use the Soft Cover. The Soft Cover ensures protection equivalent to IP54F against oil. Do not, however, use the H7CC in locations where it would come in direct contact with oil.

Waterproof Packing
Y92S-P6

H7CC-R 外觀尺寸 11

Note: The Waterproof Packing is included with models with screw terminals.
Order the Waterproof Packing separately if it is lost or damaged. The Waterproof Packing can be used to achieve IP66 protection.

The panel surface of the H7CC-A/-R is water-resistant (conforming to IP66). To protect the internal circuits from water penetration through the space between the H7CC and operating panel, waterproof packing is included. Attach the Y92F-30 Adapter with sufficient pressure with the reinforcing screws so that water does not penetrate the panel.

H7CC-R 外觀尺寸 13

The Waterproof Packing will deteriorate, harden, and shrink depending on the application environment. To ensure maintaining the IP[]6 waterproof level, periodically replace the Waterproof Packing.
The periodic replacement time will depend on the application environment. You must confirm the proper replacement time. Use 1 year or less as a guideline. If the Waterproof Packing is not replaced periodically, the waterproof level will not be maintained. It is not necessary to mount the Waterproof Packing if waterproof construction is not required.

Flush Mounting Adapter
Y92F-30

H7CC-R 外觀尺寸 15

Order the Flush Mounting Adapter with the following model number separately if it is lost or damaged.
Note: The Waterproof Packing is included with models with screw terminals.

Y92F-45

Note:
1. The adapter is black in color.
2. The Y92F-45 can be used in combination with the Y92F-30 Adapter provided with the Counter.

H7CC-R 外觀尺寸 17

H7CC Mounting Example

H7CC-R 外觀尺寸 18

Connection Sockets

Front Connecting Socket

P2CF-11

H7CC-R 外觀尺寸 21

P2CF-11-E
(Finger-safe Type)

H7CC-R 外觀尺寸 22

P2CF-08

H7CC-R 外觀尺寸 23

P2CF-08-E
(Finger-safe Type)

H7CC-R 外觀尺寸 24

Note: Round crimp terminals cannot be used on Finger-safe Sockets. Use forked crimp terminals.

Back-connecting Sockets

P3GA-11

H7CC-R 外觀尺寸 27

P3G-08

H7CC-R 外觀尺寸 28

Note: A Y92A-48G Terminal Cover can be used with the Socket to create a finger-safe construction.

Terminal Covers for P3GA-08/P3GA-11 Back-connecting Socket

Y92A-48G

H7CC-R 外觀尺寸 31

Note: The Terminal Cover can be used with a Back-mounting Socket (P3GA-11, P3G-08) to create a finger-safe construction.

Optional Products for Track Mounting

Mounting Track
PFP-100N
PFP-50N

H7CC-R 外觀尺寸 34

Mounting Track
PFP-100N2

H7CC-R 外觀尺寸 35

End Plate
PFP-M

H7CC-R 外觀尺寸 36

Spacer
PFP-S

H7CC-R 外觀尺寸 37

Note: Order Spacers in increments of 10.

English

Global Edition

以下是海外共通的產品型錄,其中可能包含不在台灣銷售的型號。

在台灣訂購時請注意確認。

※若型錄PDF檔案太大,建議按滑鼠右鍵"另存目標"下載。

Catalog Name Catalog Number
[size]
Last Update
H7CC Catalog M095-E1-03
[1055KB]
Jun 14, 2021
20210614
H7CC Catalog
H7CC Data Sheet M094-E1-04