NX-RS[][][][]

NX-RS[][][][]

產品特色
Build a cost saving weighing/ measurement system by using load cells

• Sampling as fast as 125 μs

• Accuracy applicable to high-precision load cells (nonlinearity: ±0.01% (full scale), zero drift: ±0.1 μV/°C RTI, gain drift: ±10 ppm/°C)

• Screwless clamping terminal block for easy wiring. Push-in connections speed up installation

• Stable measurements with digital filtering (digital low-pass filter, moving average filter 1, and moving average filter 2)

• Optimum digital filter design using data tracing

• Cable disconnection check using sensor disconnection test

• Connection to the CJ-series is possible by connecting with the EtherNet/IPTM Coupler.
 

Sysmac is a trademark or registered trademark of OMRON Corporation in Japan and other countries for OMRON factory automation products.
EtherCAT® is a registered trademark of Beckhoff Automation GmbH for their patented technology. EtherNet/IPTM is the trademarks of ODVA.
Other company names and product names in this document are the trademarks or registered trademarks of their respective companies.

Applicable standards

Ask your OMRON representative for the most recent applicable standards for each model.

Load Cell Input Unit

Product
name
Specification Model
Number
of points
Conversion
cycle
I/O refreshing
method *
Load cell
excitation voltage
Input range
Load Cell
Input Unit
3538_lu_1_1
1 125 μs • Free-Run refreshing
• Synchronous I/O
refreshing
• Task period prioritized
refreshing
5 VDC ± 10% -5.0 to
5.0 mV/V
NX-RS1201

* Refer to the I/O Refreshing in the NX-series Load Cell Input Unit User’s Manual (Cat. No. W565) for detailed information on I/O refresh cycle.
Note: The NX-RS1201-K Load Cell Input Unit with the test and calibration certificate is also available. Ask your OMRON representative for details.

Optional Products

Product name Specification Model
Unit/Terminal Block Coding Pins For 10 Units (Terminal Block: 30 pins, Unit: 30 pins) NX-AUX02

Product name Specification Model
No. of terminals Terminal number
indications
Ground terminal
mark
Terminal current
capacity
Terminal Block 16 A/B Provided 10 A NX-TBC162

Accessories

Not included.

General Specification

Item Specification
Enclosure Mounted in a panel
Grounding methods Ground of 100 Ω or less
Operating
environment
Ambient operating
temperature
0 to 55°C
Ambient operating
humidity
10 to 95% RH (with no icing or condensation)
Atmosphere Must be free from corrosive gases.
Ambient storage
temperature
-25 to 70°C (with no icing or condensation)
Altitude 2,000 m max.
Pollution degree Pollution degree 2 or less: Meets IEC 61010-2-201.
Noise immunity Conforms to IEC 61000-4-4, 2 kV (power supply line)
Overvoltage
category
Category II: Meets IEC 61010-2-201.
EMC immunity level Zone B
Vibration resistance Conforms to IEC 60068-2-6.
5 to 8.4 Hz with amplitude of 3.5 mm,
8.4 to 150 Hz, acceleration of 9.8 m/s2
100 min each in X, Y, and Z directions (10 sweeps of 10 min each = 100 min total)
Shock resistance Conforms to IEC 60068-2-27, 147 m/s2, 3 times each in X, Y, and Z directions
Applicable standards * cULus: Listed (UL61010-2-201), ANSI/ISA 12.12.01, EU: EN 61131-2, NK, LR,
RCM, KC: KC Registration

* Ask your OMRON representative for the most recent applicable standards for each model.

Function Specification

Supported: Functions that are used in target applications
-: Functions that are not used in target applications

Function Application Description
Weight
measurement
*1
Force
measurement
*2
I/O refreshing
ethod
setting *3
Supported. Supported. Sets Free-Run refreshing, synchronous I/O refreshing,*4 or task
period prioritized refreshing*5 for the I/O refreshing*6 method.
Actual load
calibration
Supported. Supported. This is a user calibration function that is performed by placing an
actual load on the load cell.
Equivalent input
calibration
Supported. Supported. This is a user calibration function that is performed by inputting
the rated output, rated capacity, and zero balance values of the
load cell.
Gravity
acceleration
correction
Supported. - This function corrects errors in the gross weight values that occur
due to the difference of gravity acceleration at each site when the
site where the actual load calibration of the device is executed
and the installation site are different.
Digital filtering Supported. Supported. This function uses the digital filter to remove noise components
that are contained in input signals to suppress fluctuations of
measurement values. You can use the digital low-pass filter and
moving average filter.
Zero set/
zero reset
Supported. Supported. The zero set function corrects the gross weight value/force
measurement value to be the zero point within the set range at
a desired time.
The zero reset function resets the zero point correction that is
performed with the zero set function.
Zero tracking Supported. - This function automatically corrects the zero point within the set
range.
Zero point range
over detection
Supported. Supported. This function detects when the gross weight value/force
measurement value exceeds the set zero point range.
Tare subtraction Supported. - This function subtracts the tare weight value from the gross weight
value to acquire the net weight value. There are two types of this
function: one-touch tare subtraction and digital tare subtraction.
One-touch tare
subtraction
Supported. - This function stores the gross weight value at the specified timing
as the tare value and subtracts it from a given gross weight value
to acquire the net weight value.
Digital tare
subtraction
Supported. - This function subtracts the preset digital tare value from the gross
weight value to acquire the net weight value.
Stable detection Supported. - This function detects whether the gross weight value is stable.
Over range/under
range detection
Supported. Supported. This function detects when the input signal exceeds the input
conversion range.
Sensor
disconnection
test
Supported. Supported. This function tests if the cable that connects the Load Cell Input
Unit and load cell is disconnected. During the sensor
disconnection test, you cannot measure the weight or force.
Input value
refreshing
stop
Supported. Supported. This function stops refreshing the input value in a specified period.
Peak hold/
bottom hold
- Supported. This function continues holding the peak value or the bottom
value of the force measurement value in a specified period.
Data tracing Supported. Supported. This function records the values in REAL data in the buffer of the
Load Cell Input Unit and exports the data to a CSV file.
These values indicate the gross weight values/force
measurement values before and after the digital filtering in a
specified period.
Decimal point
position setting
Supported. Supported. This function sets the number of digits which is displayed after the
decimal point for each DINT data.

*1. It is used to measure the weight in the unit of kg or t.
*2. It is used to measure the force in the unit of N or kN.
*3. Select with the Communications Coupler Unit setting. Refer to the NX-series Load Cell Input Unit User’s Manual
(W565) for details on the setting method.
*4. You can select this option only when the Unit is used with an EtherCAT Coupler Unit with EtherCAT communications
in DC Mode.
*5. You can select this option only when the Unit is used with an EtherCAT Coupler Unit NX-ECC203 with EtherCAT
communications in DC Mode.
*6. This is the data exchange with the Controller.

Individual Specifications

Load Cell Input Unit

NX-RS1201

Unit name Load Cell Input Unit Model NX-RS1201
Number of points 1 point External connection
terminals
Screwless clamping terminal block
(16 terminals)
I/O refreshing
method
Free-Run refreshing, synchronous I/O refreshing, or task period prioritized refreshing
Indicators TS indicator
3538_sp_3_1
Input range -5.0 to 5.0 mV/V
Input conversion
range
-5.5 to 5.5 mV/V
Load cell excitation
voltage
5 VDC ± 10%, Output current:
60 mA max.
Zero point adjustment
range
-5.0 to 5.0 mV/V
Gain point adjustment
range
-5.0 to 5.0 mV/V
Accuracy
*1
Nonlinearity ±0.01% (full scale) *2
Zero drift ±0.1 μV/°C RTI
Gain drift ±10 ppm/°C
A/D converter
resolution
24 bits
Warm-up period 30 minutes Conversion cycle 125 μs
Dimensions 12 (W) × 100 (H) × 71 (D) Isolation method Between the input and the NX bus:
Power = Transformer,
Signal = Digital isolator
Insulation
resistance
20 MΩ min. between isolated
circuits (at 100 VDC)
Dielectric strength 510 VAC between isolated circuits
for 1 minute at a leakage current
of 5 mA max.
I/O power supply
method
No supply Current capacity of I/O
power supply terminal
Without I/O power supply terminals
NX Unit power consumption • Connected to a CPU Unit
2.05 W max.
• Connected to a Communications
Coupler Unit
1.70 W max.
Current consumption
from I/O power supply
No consumption
Weight 70 g max.
Circuit layout 3538_sp_3_2
Installation
orientation
and restrictions
Installation orientation:
• Connected to a CPU Unit: Possible in upright installation.
• Connected to a Communications Coupler Unit: Possible in 6 orientations.
Restrictions: No restrictions
Terminal
connection
diagram

Diagram of the 6-wire connection between the Unit and a load cell.
3538_sp_3_3


Diagram of the 4-wire connection between the Unit and a load cell.
3538_sp_3_4

*1. Accuracy for when the load cell and the Load Cell Input Unit are connected with the 6-wire connection.
*2. The value for when the Load Cell Unit is used under the following conditions.
Full scale: 0.0 to 5.0 mV/V or -5.0 to 0.0 mV/V
Ambient temperature: 25°C
Setting of digital filtering: Default

Version Information

Connecting with CPU Units

Refer to the user's manual for the CPU Unit for the CPU Unit to which NX Units can be connected.

NX Unit Corresponding unit versions/versions
Model Unit version CPU Unit Sysmac Studio
NX-RS1201 Ver.1.0 Ver.1.13 Ver.1.17

Note: Some Units do not have all of the versions given in the above table. If a Unit does not have the specified version,
support is provided by the oldest available version after the specified version. Refer to the user’s manuals for the
specific Units for the relation between models and versions.

Connecting with an EtherCAT Coupler Units

NX Unit Corresponding unit versions/versions
EtherCAT
Model Unit version EtherCAT Coupler Unit CPU Units or Industrial PCs Sysmac Studio
NX-RS1201 Ver.1.0 Ver.1.0 Ver.1.05 Ver.1.16

Note: Some Units do not have all of the versions given in the above table. If a Unit does not have the specified version,
support is provided by the oldest available version after the specified version. Refer to the user’s manuals for the
specific Units for the relation between models and versions.

Connecting with EtherNet/IP Coupler Unit

NX Unit Corresponding unit versions/versions
Application with an NJ/NX/NY-series
Controller *1
Application with a CS/CJ/CP-series
PLC *2
Model Unit version EtherNet/IP
Coupler Unit
CPU Unit or
Industrial PC
Sysmac
Studio
EtherNet/IP
Coupler Unit
Sysmac
Studio
NX-IO
Configurator
*3
NX-RS1201 Ver. 1.0 Ver. 1.2 Ver. 1.14 Ver. 1.19 Ver. 1.0 Ver. 1.16 Ver. 1.00

Note: Some Units do not have all of the versions given in the above table. If a Unit does not have the specified version,
support is provided by the oldest available version after the specified version. Refer to the user's manuals for the
specific Units for the relation between models and versions.
*1. Refer to the user’s manual for the EtherNet/IP Coupler Units for information on the unit versions of EtherNet/IP Units
that are compatible with EtherNet/IP Coupler Units.
*2. Refer to the user’s manual for the EtherNet/IP Coupler Units for information on the unit versions of CPU Units and
EtherNet/IP Units that are compatible with EtherNet/IP Coupler Units.
*3. For connection to an EtherNet/IP Coupler Unit with unit version 1.0, You can connect only to the peripheral USB port on
the EtherNet/IP Coupler Unit. You cannot connect with any other path. If you need to connect by another path, use an
EtherNet/IP Coupler Unit with unit version 1.2 or later.

(單位:mm)

NX-RS1201

NX-RS[][][][] 外觀尺寸 1

中文

※若型錄PDF檔案太大,建議按滑鼠右鍵"另存目標"下載。

型錄名稱 型錄編號
[容量]
更新日期
NX系列 IO系統 產品型錄 SBCD-083-TW5
[20827KB]
2022年9月5日
20220905
NX系列 IO系統 產品型錄

English

Global Edition

以下是海外共通的產品型錄,其中可能包含不在台灣銷售的型號。

在台灣訂購時請注意確認。

※若型錄PDF檔案太大,建議按滑鼠右鍵"另存目標"下載。

Catalog Name Catalog Number
[size]
Last Update
NX-RS[][][][] Data Sheet -
[2230KB]
Oct 11, 2022
20221011
NX-RS[][][][] Data Sheet
NX-series I/O System Catalog R183-E1-15
[6288KB]
Jul 19, 2022
20220719
NX-series I/O System Catalog
如有需要請洽各所營業人員

誠睿台南所 TEL:06-2493086
誠睿台中所 TEL:04-23380790
誠睿新竹所 TEL:03-6685558
客服信箱 service@hitifa.com.tw
如有需要請洽各所營業人員

誠睿台南所 TEL:06-2493086
誠睿台中所 TEL:04-23380790
誠睿新竹所 TEL:03-6685558
客服信箱 service@hitifa.com.tw
更多案例 更多產品 TOP