商品搜尋
商品搜尋
行業別
功能
Banner

產品&服務

HITI Industrial Automation

• Fast data exchange between EtherCAT master and CPU Unit.

• Adjustable data exchange sizes.

• Node address setting by rotary switches or software.

• Easy integration of networks used by CJ/NJ Series with EtherCAT.

International Standards

  • • The standards are abbreviated as follows: U: UL, U1: UL (Class I Division 2 Products for Hazardous Locations), C: CSA, UC: cULus, UC1: cULus (Class I Division 2 Products for Hazardous Locations), CU: cUL, N: NK, L: Lloyd, CE: EC Directives, and KC: KC Registration.
    • Contact your OMRON representative for further details and applicable conditions for these standards.

EtherCAT Slave Unit

Unit
type
Product
name
Specifications No. of
unit
numbers
allocated
Current con-
sumption (A)
Model Stand-
ards
Communica-
tions cable
Communications
functions
5 V
system
24 V
system
CJ1
CPU
Bus
Unit
EtherCAT
Slave Unit
3439_lu_1_1
STP (shielded
twisted-pair)
cable of category
5 or higher with
double shielding
Refreshing methods:
Free-Run Mode
PDO data sizes:
TxPDO 400byte max./
RxPDO: 400byte max.
1 0.34 -- CJ1W-ECT21
*
UC1,
CE,
KC

* When using with the Machine Automation Controller NJ /NXSeries, use CPU Units with unit version 1.10 or later and the Sysmac Studio version 1.13 or higher.

Recommended EtherCAT Communications Cable

Use a straight STP (shielded twisted-pair) cable of category 5 or higher with double shielding (braiding and aluminum foil tape) for EtherCAT.

Cable with Connectors

Item Appearance Recom-
mended
manu-
facturer
Cable
length
[m] *1
Model
Cable with Connectors on Both Ends
(RJ45/RJ45)
Standard RJ45 plugs type *1
Wire gauge and number of pairs: AWG26,
4-pair cable
Cable sheath material: LSZH *2
Cable color: Yellow *3
3439_lu_2_1 OMRON 0.3 XS6W-6LSZH8SS30CM-Y
0.5 XS6W-6LSZH8SS50CM-Y
1 XS6W-6LSZH8SS100CM-Y
2 XS6W-6LSZH8SS200CM-Y
3 XS6W-6LSZH8SS300CM-Y
5 XS6W-6LSZH8SS500CM-Y
Cable with Connectors on Both Ends
(RJ45/RJ45)
Rugged RJ45 plugs type *1
Wire gauge and number of pairs: AWG22,
2-pair cable
Cable color: Light blue
3439_lu_2_2 OMRON 0.3 XS5W-T421-AMD-K
0.5 XS5W-T421-BMD-K
1 XS5W-T421-CMD-K
2 XS5W-T421-DMD-K
5 XS5W-T421-GMD-K
10 XS5W-T421-JMD-K
Cable with Connectors on Both Ends
(M12 Straight/M12 Straight)
Shield Strengthening Connector cable *4
M12/Smartclick Connectors
Wire Gauge and Number of Pairs: AWG22,
2-pair Cable
Cable color: Black
3439_lu_2_3 OMRON 0.5 XS5W-T421-BM2-SS
1 XS5W-T421-CM2-SS
2 XS5W-T421-DM2-SS
3 XS5W-T421-EM2-SS
5 XS5W-T421-GM2-SS
10 XS5W-T421-JM2-SS
Cable with Connectors on Both Ends
(M12 Straight/RJ45)
Shield Strengthening Connector cable *4
M12/Smartclick Connectors
Rugged RJ45 plugs type
Wire Gauge and Number of Pairs: AWG22,
2-pair Cable
Cable color: Black
3439_lu_2_4 OMRON 0.5 XS5W-T421-BMC-SS
1 XS5W-T421-CMC-SS
2 XS5W-T421-DMC-SS
3 XS5W-T421-EMC-SS
5 XS5W-T421-GMC-SS
10 XS5W-T421-JMC-SS

*1. Standard type cables length 0.2, 0.3, 0.5, 1, 1.5, 2, 3, 5, 7.5, 10, 15 and 20 m are available.
Rugged type cables length 0.3, 0.5, 1, 2, 3, 5, 10 and 15 m are available.
For details, refer to Cat.No.G019.
*2. The lineup features Low Smoke Zero Halogen cables for in-cabinet use and PUR cables for out-of-cabinet use.
Although the LSZH cable is single shielded, its communications and noise characteristics meet the standards.
*3. Cables colors are available in blue, yellow, or Green.
*4. For details, contact your OMRON representative.

Cable / Connectors

Wire Gauge and Number of Pairs: AWG24, 4-pair Cable

Item Appearance Recommended manufacturer Model
Cables ---- Hitachi Metals, Ltd. NETSTAR-C5E SAB 0.5 × 4P CP *
---- Kuramo Electric Co. KETH-SB *
RJ45 Connectors ---- Panduit Corporation MPS588-C *

* We recommend you to use above cable and connector together.

Wire Gauge and Number of Pairs: AWG22, 2-pair Cable

Item Appearance Recommended manufacturer Model
Cables ---- Kuramo Electric Co. KETH-PSB-OMR *
---- JMACS Japan Co., Ltd. PNET/B *
RJ45 Assembly Connector 3439_lu_4_1 OMRON XS6G-T421-1 *

* We recommend you to use above cable and connector together.
Note: Connect both ends of cable shielded wires to the connector hoods.

General Specification

The general specifications conform to those of the CJ-series PLCs, CP-series PLCs and NSJ-series PLCs *1.
*1. NSJ-series is no longer available to order.

Specifications

EtherCAT Slave Unit CJ1W-ECT21

Item Specification
Model number CJ1W-ECT21
Applicable PLCs NJ-series, CJ-series, CP-series, NSJ-series *1
Unit classification CPU Bus Unit
Applicable unit numbers 0 to F
Mounting position CPU Rack or Expansion Rack
Number of Units that can be mounted 16 Units max. (you must allocate unique words)
CPU Unit
words used
Allocated CIO Area words
(CPU Bus Unit words) *2
25 words/Unit (one unit number’s words)
Unit Status 1, Unit Status 2, Slave Status 1, Slave Status 2
Allocated DM Area words
(CPU Bus Unit words) *3
100 words/Unit (one unit number’s words)
I/O Communication Area Setting Table, I/O Communication Area
Reference Table
Other I/O memory *4 I/O communication area in any area *5
CPU Bus Unit setting area Not used
Transmission
specifications
Communications protocol EtherCAT protocol
Modulation Baseband
Baud rate 100 Mbps
Physical layer 100BASE-TX (IEEE 802.3)
Topology Depends on the specifications of the EtherCAT master
Transmission media Category 5 or higher twisted-pair cable (Recommended cable:
double-shielded cable with aluminum tape and braiding)
Transmission distance Distance between nodes: 100 m or less
Send/receive PDO data sizes Allocatable IN and OUT data area sizes of 0, 50, 100, 200 or 400 bytes
Mailbox data size Input: 512 bytes
Output: 512 bytes
Mailbox Emergency messages and SDO requests
Refreshing methods Free-Run Mode
Node address setting range 1 to 255 (hardware switch setting)
1 to 65535 (software switch setting)
Current consumption 340 mA max. at 5 V DC
Weight 97 g max.
Dimensions 31 × 90 × 65 mm (W × H × D)

*1. NSJ-series is no longer available to order.
*2. Access via the device variables for CJ-series Unit when using NJ-serires CPU Units.
*3. Using the user-defined variable for R/W to the allocation area when using NJ-serires CPU Units.
*4. The IN and OUT data exchanged with the EtherCAT master is designated to memory areas by configuring the I/O
Communication Area Setting Table. Refer to “CJ-series EtherCAT Slave Units Operation Manual” for NJ-series CPU Unit
(W542)
*5. Set with allocated DM area words (CPU Bus Unit words) or CX-Programmer when using CJ/CP/NSJ-series CPU Units.

EtherCAT Communications Specifications

Item Specification
Communications standard IEC 61158 Type 12
Physical layer 100BASE-TX (IEEE 802.3)
Modulation Baseband
Baud rate 100 Mbps
Topology Depends on the specifications of the EtherCAT master.
Transmission media Category 5 or higher twisted-pair cable (Recommended cable: double-shielded cable
with aluminum tape and braiding)
Transmission distance Distance between nodes: 100 m or less

Unit Versions and Software Versions

Model mumber of
EtherCAT Slave Unit
Unit
version
Corresponding unit version/version *
Using NJ CPU Unit Using CJ/CP/NSJ-series CPU Unit
Unit version of
CPU Units
Sysmac Studio
Version
Unit version of
CPU Units
CX-Programmer
version
CJ1W-ECT21 Ver.1.0 Ver.1.10 or later Ver.1.13 or higher The oldest available
version or later
Ver.9.54 or higher

* Some Units do not have all of the versions given in the above table. If a Unit does not have the specified version, support is provided by the oldest available version after the specified version. Refer to the user’fs manuals for the specific Units for the relation between models and versions.

(單位:mm)

CJ1W-ECT21

CJ1W-ECT21 外觀尺寸 1

English

Global Edition

以下是海外共通的產品型錄,其中可能包含不在台灣銷售的型號。

在台灣訂購時請注意確認。

※若型錄PDF檔案太大,建議按滑鼠右鍵"另存目標"下載。

Catalog Name Catalog Number
[size]
Last Update
CJ1W-ECT21 Data Sheet -
[951KB]
Oct 11, 2022
20221011
CJ1W-ECT21 Data Sheet
如有需要請洽各所營業人員

誠睿台南所 TEL:06-2493086
誠睿台中所 TEL:04-23380790
誠睿新竹所 TEL:03-6685558
客服信箱 service@hitifa.com.tw
如有需要請洽各所營業人員

誠睿台南所 TEL:06-2493086
誠睿台中所 TEL:04-23380790
誠睿新竹所 TEL:03-6685558
客服信箱 service@hitifa.com.tw
更多案例 更多產品 TOP