CK3E

CK3E

產品特色
A controller with a width of only 28.6 mm provides complete control
CK3E 特長 1

High-speed multi-axis control
· Up to 32 axes of control
· Motion control period: 250 μs or more

CK3E 特長 2

Flexibility
· CAD/CAM for easy motion control
· Flexible function development capability enables high-precision curve machining

CK3E 特長 3

Saving space & wiring
· Footprint reduced to 1/4 (Based on Omron investigation)
· EtherCAT for flexible system configuration

One of Omron's aims is to help manufacturers build High-speed advanced Motion Control systems at a low cost

In order to achieve this, Omron and Delta Tau Data Systems, Inc. are working together as one Omron Group to improve sophisticated Motion Control and Programmable Logic Control systems. These are the systems that are required for the next generation's automation systems around the world.
By combining global leading Delta Tau Data Systems' Motion Control technologies, Omron ILO+S (Input, Logic, Output, and Safety) control technologies can open up new applications and solutions.
The CK3E is a controller designed for precise multi-axis control.
You can build a system capable of controlling up to 32 axes of motion and incorporate customized control algorithms into the system.
The CK3E allows you to program in C language and reuse existing software assets.
The compact design saves space in machines and control panels. EtherCAT® connects servo drives, I/O, and other devices to the CK3E, reducing the number of cables.

Product Specifications Model
Memory Ports Max. no. of controlled axes
at EtherCAT port
Programmable
Multi-Axis Controller
Main memory: 1 GB
Flash memory: 1 GB
EtherNet/IP port: 1
EtherCAT port: 1
8 CK3E-1210
16 CK3E-1310
32 CK3E-1410

Optional Hardware

Product name Specifications Model
USB Flash Drives Capacity: 2 GB FZ-MEM2G
Capacity: 8 GB FZ-MEM8G
Power supply Output voltage: 24 VDC S8FS-G[][][]24[]

Recommended EtherCAT Communications Cables

Use Straight STP (shielded twisted-pair) cable of category 5 or higher with double shielding (braiding and aluminum foil tape) for EtherCAT.
For EtherCAT, use a shielded twisted-pair cable (double shielding with aluminum tape and braiding) of Ethernet category 5 (100BASETX) or higher, and use straight wiring.
For Ethernet, required specification for the communications cables varies depending on the baud rate.
For 100BASE-TX/10BASE-T, use an STP (shielded twisted-pair) cable of Ethernet category 5 or higher. You can use either a straight or cross cable.
For 1000BASE-T, use an STP (double shielding with aluminum tape and braiding) cable of Ethernet category 5e or higher. You can use either a straight or cross cable.
In the table, materials indicated available for Ethernet 100BASE-TX are available for both of 100BASE-TX and 10BASE-T.

Cable with Connectors

Item Appearance Recom-
mended
manu-
facturer
Cable
length
(m)
Model
Products
for
EtherCAT
Cable with Connectors on Both Ends
(RJ45/RJ45)
Standard RJ45 plugs type *1
Wire Gauge and Number of Pairs:
AWG26, 4-pair Cable
Cable Sheath material: LSZH *2
Cable color: Yellow *3
3545_lu_3_1 OMRON 0.3 XS6W-6LSZH8SS30CM-Y
0.5 XS6W-6LSZH8SS50CM-Y
1 XS6W-6LSZH8SS100CM-Y
2 XS6W-6LSZH8SS200CM-Y
3 XS6W-6LSZH8SS300CM-Y
5 XS6W-6LSZH8SS500CM-Y
Cable with Connectors on Both Ends
(RJ45/RJ45)
Rugged RJ45 plugs type *1
Wire Gauge and Number of Pairs:
AWG22, 2-pair Cable
Cable color: Right blue
3545_lu_3_2 OMRON 0.3 XS5W-T421-AMD-K
0.5 XS5W-T421-BMD-K
1 XS5W-T421-CMD-K
2 XS5W-T421-DMD-K
5 XS5W-T421-GMD-K
10 XS5W-T421-JMD-K
Cable with Connectors on Both Ends
(M12 Straight/M12 Straight)
Shield Strengthening Connector
cable *4
M12/Smartclick Connectors
Wire Gauge and Number of Pairs:
AWG22, 2-pair Cable
Cable color: Black
3545_lu_3_3 OMRON 0.5 XS5W-T421-BM2-SS
1 XS5W-T421-CM2-SS
2 XS5W-T421-DM2-SS
3 XS5W-T421-EM2-SS
5 XS5W-T421-GM2-SS
10 XS5W-T421-JM2-SS
Cable with Connectors on Both Ends
(M12 Straight/RJ45)
Shield Strengthening Connector
cable *4
M12/Smartclick Connectors
Rugged RJ45 plugs type
Wire Gauge and Number of Pairs:
AWG22, 2-pair Cable
Cable color: Black
3545_lu_3_4 OMRON 0.5 XS5W-T421-BMC-SS
1 XS5W-T421-CMC-SS
2 XS5W-T421-DMC-SS
3 XS5W-T421-EMC-SS
5 XS5W-T421-GMC-SS
10 XS5W-T421-JMC-SS

*1. Standard type cables length 0.2, 0.3, 0.5, 1, 1.5, 2, 3, 5, 7.5, 10, 15 and 20 m are available.
Rugged type cables length 0.3, 0.5, 1, 2, 3, 5, 10 and 15 m are available.
For details, refer to Cat.No.G019.
*2. The lineup features Low Smoke Zero Halogen cables for in-cabinet use and PUR cables for out-of-cabinet use.
Although the LSZH cable is single shielded, its communications and noise characteristics meet the standards.
*3. Cables colors are available in blue, yellow, or Green.
*4. For details, contact your OMRON representative.

Cables / Connectors

Item Recommended
manufacturer
Model
Products for EtherCAT
or Ethernet
(1000BASE-T/
100BASE-TX)
Wire Gauge and Number
of Pairs: AWG24, 4-pair
Cable
Cables Hitachi Metals, Ltd. NETSTAR-C5E SAB
0.5 × 4P CP *1
Kuramo Electric Co. KETH-SB *1
RJ45
Connectors
Panduit Corporation MPS588-C *1
Products for EtherCAT
or Ethernet
(100BASE-TX)
Wire Gauge and Number
of Pairs: AWG22, 2-pair
Cable
Cables Kuramo Electric Co. KETH-PSB-OMR *2
JMACS Japan Co., Ltd. PNET/B *2
RJ45 Assembly
Connector
3545_lu_4_1
OMRON XS6G-T421-1 *2

*1. We recommend you to use above cable for EtherCAT and Ethernet, and RJ45 Connector together.
*2. We recommend you to use above cable for EtherCAT and Ethernet, and RJ45 Assembly Connector together.
Note: Connect both ends of cable shielded wires to the connector hoods.

Support Software

The following table shows the Support Software used to configure, monitor, program, and debug the Programmable Multi-Axis Controller.

Software Name Application How to Procure
Power PMAC IDE * This computer software is used to configure
the Controller, create user programs, and
debug the programs.
This is free software.
Contact your OMRON representative
for information on how to procure.
Power PMAC
NC
Power PMAC-NC
SDK
This computer software is used to control
working machines and other CNC machines
with the Controller. Use this software when
you want to customize the HMI screen. The
product contains extension source codes
used for customization.
This is non-free software.
Contact your OMRON representative
for information on how to procure.
Power PMAC-NC
Runtime
This computer software is used to control
working machines and other CNC machines
with the Controller. Use this software when
you do not customize the HMI screen.
This is non-free software.
Contact your OMRON representative
for information on how to procure.
EC Engineer This computer software is used to configure
and monitor the EtherCAT network by using
the Controller as the EtherCAT master.
This is free software.
Contact your OMRON representative
for information on how to procure.

Note: PMAC is an abbreviation for Programmable Multi Axis Controller.
* For CK3E version 2.3 or earlier, use Power PMAC IDE version 2.2 or later. For CK3E version 2.4 or later, use Power PMAC IDE version 4.1 or later.

General Specifications

Item Specification
CK3E-1210 CK3E-1310 CK3E-1410
Enclosure Mounted in a panel
Grounding method Ground to 100 Ω or less
Dimensions (height × width × depth) 130.4(H) × 28.6(D) × 170.9(W) mm
Weight 540 g or less
Unit power supply rated voltage 24 VDC (20.4 to 26.4 VDC)
Unit power supply current consumption 660 mA or less
Operating
environment
Ambient operating temperature 0 to 45°C
Ambient operating humidity 10 to 95% RH (without condensation and icing)
Atmosphere Must be free from corrosive gases.
Ambient storage temperature -25 to +70°C (without condensation and icing)
Vibration resistance Conforms to IEC 60068-2-6.
5 to 8.4 Hz with amplitude of 3.5 mm, 8.4 to 150 Hz, acceleration
of 9.8 m/s2
100 min each in X, Y, and Z directions (10 sweeps of 10 min each
= 100 min total)
Shock resistance Conforms to IEC 60068-2-27, 147 m/s2, 3 times each in X, Y, and
Z directions
Applicable standards * EU: EN 61326, RCM, KC Registration, UL

* For the latest applicable standards for each model, contact your OMRON representative.

Performance/Function Specifications

Item Specification
CK3E-1210 CK3E-1310 CK3E-1410
Memory Main memory: 1 GB
Flash memory: 1 GB
External terminals Communications Connector
For EtherCAT communications.
• RJ45 × 1 (Shield supported)
For Ethernet communications.
• RJ45 × 1 (Shield supported)
Power supply input terminal
For Unit power supply × 1
USB port
For external memory connection, USB 3.0 host × 1 Type A
Motion
control
Maximum Number of
Controlled Axes
8 axes 16 axes 32 axes
Motion control period 250 μs or more
Control method Issuing control commands using EtherCAT communications
EtherCAT
commu-
nications
specifi-
cations
Communications protocol EtherCAT protocol
Baud rate 100 Mbps
Physical layer 100BASE-TX (IEEE 802.3)
Topology Line, daisy chain, and branching
Transmission media Twisted-pair cable of category 5 or higher (double-shielded cable
with aluminum tape and braiding)
Transmission distance Distance between nodes: 100 m or less
Maximum number of slaves 32
Range of node addresses that
can be set
1 to 32
Ethernet
Port
Baud rate 100 Mbps
Physical layer 100BASE-TX (IEEE 802.3)
Frame length 1,514 bytes max.
Media access method CSMA/CD
Modulation Baseband
Topology Star
Transmission media Twisted-pair cable of category 5, 5e, or higher (shielded cable) *1
Maximum transmission
distance between Ethernet
switch and node
100 m
Maximum number of cascade
connections
There are no restrictions if an Ethernet switch is used.
EtherNet/lP
tag data link
(cyclic
communica-
tions)
*2
Number of
connections
32
Requested packet
interval (RPI)
1 to 1,000 ms (0.5 ms units)
Allowed
communications
bandwidth per Unit
3,200 pps *3
IO connection size Input: 504 bytes max.
Output: 504 bytes max.
EtherNet/lP
CIP message
service *2
UCMM
(unconnected
message)
Number of servers that can perform communications
simultaneously: 32
EtherNet/lP conformance test CT17 comoliant
USB port Physical layer USB 3.0-compliant A-type connector, Output voltage 5 V, 0.9 A max.
Transmission distance 3 m max.

*1. Always use shielded cables for EtherNeUIP communications.
*2. EtherNet/IP is available only for targets and not available for originators. EtherNet/IP is available only for PMAC
firmware revision version 2.6.0 or later whose date of production is September ??, 2020 or later (Lot number ??920
and later). Use Power PMAC IDE Ver.4.4.1 or a later version.
*3. Represents Packet Per Second and indicates the number of sent or received packets that can be processed in a second.

Restrictions on using the OMRON NX-Series Ethercat Coupler Unit

When OMRON NX-series EtherCAT Coupler Units are used as slaves of the Programmable Multi-Axis Controller as the EtherCAT master, the following models and unit versions of EtherCAT Coupler Units can be connected.

Model Unit version Connectable/Unconnectable
NX-ECC203 Ver. 1.4 or later Connectable
Ver. 1.3 or earlier Unconnectable
NX-ECC202 All versions
NX-ECC201 All versions

(單位:mm)

Main Body Only

CK3E 外觀尺寸 1

With Power Connector

CK3E 外觀尺寸 2

Mounting Dimensions

CK3E 外觀尺寸 3

中文

※若型錄PDF檔案太大,建議按滑鼠右鍵"另存目標"下載。

型錄名稱 型錄編號
[容量]
更新日期
PMAC系列型錄 SBCE-094-TW5
[2358KB]
2017年9月12日
20170912
PMAC系列型錄

English

Global Edition

以下是海外共通的產品型錄,其中可能包含不在台灣銷售的型號。

在台灣訂購時請注意確認。

※若型錄PDF檔案太大,建議按滑鼠右鍵"另存目標"下載。

Catalog Name Catalog Number
[size]
Last Update
CK3E Catalog R188-E1-01
[908KB]
Aug 01, 2016
20160801
CK3E Catalog
CK3E Data Sheet -
[1182KB]
Feb 03, 2022
20220203
CK3E Data Sheet
PMAC Series Catalog R192-E1-05
[24821KB]
Apr 01, 2022
20220401
PMAC Series Catalog
FA Controller Catalog P090-E1-11
[10256KB]
Dec 20, 2021
20211220
FA Controller Catalog
EtherNet/IP™ Catalog R150-E1-24
[4494KB]
May 23, 2022
20220523
EtherNet/IP™ Catalog
如有需要請洽各所營業人員

誠睿台南所 TEL:06-2493086
誠睿台中所 TEL:04-23380790
誠睿新竹所 TEL:03-6685558
客服信箱 service@hitifa.com.tw
如有需要請洽各所營業人員

誠睿台南所 TEL:06-2493086
誠睿台中所 TEL:04-23380790
誠睿新竹所 TEL:03-6685558
客服信箱 service@hitifa.com.tw
更多案例 更多產品 TOP